fix: codify split roof and campus assembly
Some checks failed
ci / test (macos-latest, 3.10) (push) Has been cancelled
ci / test (macos-latest, 3.12) (push) Has been cancelled
ci / test (ubuntu-latest, 3.10) (push) Has been cancelled
ci / test (ubuntu-latest, 3.12) (push) Has been cancelled
ci / test (windows-latest, 3.10) (push) Has been cancelled
ci / test (windows-latest, 3.12) (push) Has been cancelled
ci / browser-smoke (push) Has been cancelled
Some checks failed
ci / test (macos-latest, 3.10) (push) Has been cancelled
ci / test (macos-latest, 3.12) (push) Has been cancelled
ci / test (ubuntu-latest, 3.10) (push) Has been cancelled
ci / test (ubuntu-latest, 3.12) (push) Has been cancelled
ci / test (windows-latest, 3.10) (push) Has been cancelled
ci / test (windows-latest, 3.12) (push) Has been cancelled
ci / browser-smoke (push) Has been cancelled
This commit is contained in:
2
SKILL.md
2
SKILL.md
@@ -46,7 +46,9 @@ Read only the branches needed for the current task:
|
|||||||
- Use `detect_sheet_frames.py` for multi-frame sheets. If the source report finds two or more plan identities in one drawing, `--frames` is mandatory; do not let `frame_ledger` become `NOT_APPLICABLE`.
|
- Use `detect_sheet_frames.py` for multi-frame sheets. If the source report finds two or more plan identities in one drawing, `--frames` is mandatory; do not let `frame_ledger` become `NOT_APPLICABLE`.
|
||||||
- Treat detector clips as proposals. If Revit views share world coordinates, keep the detector's per-floor `include_block_names` plus top-level `expand_block_names`; clips alone cannot separate overlapping views. For non-Revit overlap, split by title/wall clusters. Area and cross-floor gates must pass before modeling.
|
- Treat detector clips as proposals. If Revit views share world coordinates, keep the detector's per-floor `include_block_names` plus top-level `expand_block_names`; clips alone cannot separate overlapping views. For non-Revit overlap, split by title/wall clusters. Area and cross-floor gates must pass before modeling.
|
||||||
- Keep `屋面平面图` (`RF`) and `机房小屋面` (`PH`) as distinct source identities. One overlapping RF clip may not satisfy both; resolve their view-suffixed blocks, heights, and roof-cap roles from the drawing evidence.
|
- Keep `屋面平面图` (`RF`) and `机房小屋面` (`PH`) as distinct source identities. One overlapping RF clip may not satisfy both; resolve their view-suffixed blocks, heights, and roof-cap roles from the drawing evidence.
|
||||||
|
- When RF and PH are both floor keys, put them in separate `cap_groups` and give each an explicit evidence-derived `roof_specs` elevation. This prevents the automatic setback-cap calculation from creating a duplicate full-roof plate between the main roof and machine-room roof.
|
||||||
- Model each building separately before campus assembly.
|
- Model each building separately before campus assembly.
|
||||||
|
- A campus request must run and audit one config per building, then use `assemble_campus.py`; do not merge building configs into one shortcut run, even when their source coordinates already share a site system.
|
||||||
- For multi-building/campus requests, write `scope_manifest.json` before modeling. Copy every requested building ID from the user/source inventory; never shrink scope to the easiest drawing set.
|
- For multi-building/campus requests, write `scope_manifest.json` before modeling. Copy every requested building ID from the user/source inventory; never shrink scope to the easiest drawing set.
|
||||||
- Use `--converter oda` plus `extract_3d_solids.py` for known 3DSOLID/ACIS drawings. For ordinary DWG input, `--converter auto` tries native LibreDWG, then the packaged WASM bridge, then ODA; do not manually assemble the WASM commands unless the report records a converter failure.
|
- Use `--converter oda` plus `extract_3d_solids.py` for known 3DSOLID/ACIS drawings. For ordinary DWG input, `--converter auto` tries native LibreDWG, then the packaged WASM bridge, then ODA; do not manually assemble the WASM commands unless the report records a converter failure.
|
||||||
- Stop and request DWG/DXF/vector conversion for PDF-only input.
|