fix: close audited CAD delivery gate gaps
This commit is contained in:
@@ -185,6 +185,14 @@ Use `origin_strategy: "center"` for large CAD coordinates. It mirrors the A208 p
|
||||
|
||||
Use `clip` rectangles for irregular sheet layouts. Use `split_x` plus `side` when a sheet cleanly places plans left/right; this is less likely to accidentally cut off geometry than a tight clip rectangle.
|
||||
|
||||
Arm cross-evidence checks whenever the drawings contain the evidence:
|
||||
|
||||
- Copy per-floor areas from the 经济技术指标表/area labels into `declared_areas_m2`; use `declared_area_tolerance` only for a justified source convention. A model area off by roughly 100% usually means two plans or two wings were swallowed into one clip, not balcony noise.
|
||||
- Copy the above-ground count from 总图 labels or elevation/section ladders into `expected_storeys_above_ground`. When one typical plan represents a range, instantiate those floors and record that they are source-supported repetitions.
|
||||
- Pass every frame-detector config through `--frames`; list deliberately unused frames in `discarded_frames` with reasons.
|
||||
|
||||
These checks report `NOT_APPLICABLE` when no independent evidence exists. That is not proof of correctness; document what was searched before leaving them unarmed.
|
||||
|
||||
Keep `expand_blocks` false for the first pass. If the audit shows important geometry in `INSERT`, set `expand_blocks` to `true` or to a list of block-name patterns, then rerun extraction/audit/overlays. When virtual block entities live on layer `0`, `block_insert_layer_fallback: true` lets the parent INSERT layer participate in category matching.
|
||||
|
||||
## 5. Spec Extraction
|
||||
@@ -203,6 +211,7 @@ Review `building_spec.json` before rendering:
|
||||
- Segment counts are not dominated by dimensions/hatches/annotations.
|
||||
- Footprint polygons exist when slabs/roofs are meant to follow CAD floor plates.
|
||||
- `default_disabled_categories` does not hide `slab` for presentation/digital-twin views.
|
||||
- Generated cap edges do not protrude as slab fins. The historical `cap_buffer=1.3m` value fits colonnade/overhang cases; use about `0.1m` for ordinary facade-aligned floors, then confirm front/side views.
|
||||
|
||||
## 6. Agent Audit and Overlay Review
|
||||
|
||||
@@ -238,6 +247,7 @@ Agent review rules:
|
||||
- If frequent blocks appear in the audit, inspect block names and decide whether to recursively explode block geometry.
|
||||
- If hatches carry wall/slab/column information, do not rely only on line extraction.
|
||||
- Continue only when missing geometry is acceptable for the requested output level.
|
||||
- A floor can be internally self-consistent yet occupy the wrong repeated slot. If wall-profile correlation finds a strong non-zero shift, treat it as the 13号 F3 “错槽” pattern and correct the frame offset rather than trusting envelope centers.
|
||||
|
||||
## 7. Blender Generation
|
||||
|
||||
|
||||
Reference in New Issue
Block a user