Productize site machinery + config automation (session-proven -> scripts/)
- register_site_outlines.py: point-to-edge ICP registration CLI (footprint union vs site outline / DIM_COOR corners), manifest-ready output, loud warning above 2 m residual - massing_from_outline.py: honest massing spec CLI (outline x storeys x height, labeled 总图轮廓体量), manifest anchors on stdout - detect_sheet_frames: multi-floor titles (四、六、八 / 十一至十四) expand to per-storey config entries sharing clip/offset — the 13号 b2 silent-floor- loss class is now prevented at the source; compound CN numerals parsed (十一/二十一 no longer collapse to F0 keys); per-frame DIM_ELEV ladders + uniform-step storey suggestion in the report (evidence, not auto-filled z) - 27号 2# real data: 19-storey enumerated title auto-expands, step 3.0 x 11 suggestion correct; regression suite +11 checks Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
6
SKILL.md
6
SKILL.md
@@ -82,7 +82,7 @@ The pipeline is designed so a first pass either succeeds or STOPS at a loud gate
|
||||
- Use `references/pipeline.md` and `references/building_spec_schema.md`.
|
||||
- Map CAD layers to normalized categories: `walls`, `glazing`, `roof`, `columns`, `beams`, `railings`, `doors`, `detail_lines`, `floor_lines`, and `grid`.
|
||||
- Identify one drawing per floor or split sheets that contain multiple floor plans side by side.
|
||||
- MULTI-FRAME SHEETS (the common Chinese pattern: one DWG per building holding ALL its plans + elevations + sections stacked in modelspace): run `scripts/detect_sheet_frames.py` on the sanitized DXF. It finds `XX平面图` title texts (filtering catalog rows and title-block copies; titles INSIDE cached-xref blocks are scanned too), prefers title-block frame INSERTs (`A0_V1`/`A0+0.5_V1`/`*图框*`… world bboxes) as clip windows — pitch-sized windows halve elongated sheets (13号 加长A0 held two towers in one frame) — refines each clip to the wall bbox inside it, and computes per-floor `offset`s by voting-based grid-line correlation (label-free; TArch grids live on layer `DOTE`, not `AXIS`). When a frame has NO axis geometry at all, it falls back to wall-profile correlation (length-weighted wall-position histograms, x and y independently, coverage+peak-ratio gated) before surrendering to the clip-corner anchor — clip corners track wall bboxes and drift by whole bays when balconies differ. Auxiliary-titled frames (非机动坡道/无障碍改造/人防…) are flagged and never become the alignment reference (a bike-ramp frame once anchored a whole tower to nothing). Never model such a file as one floor (all sheets superimpose) and never stack frames without offsets (floors staircase away diagonally — the classic broken output). Read its report: `WEAK grid match` floors need overlay verification; `wall-correlated` floors deserve one overlay check too; elevation/section frames are listed for floor heights (`z`/`height` from DIM_ELEV 标高 texts like `8.100`), not as floors. Frame clips can swallow the sheet above/below (refine bbox includes between-sheet strips): if a floor's footprint depth is ~2-4x its siblings, cluster its wall y-midpoints and cut the clip band to the plan's own row.
|
||||
- MULTI-FRAME SHEETS (the common Chinese pattern: one DWG per building holding ALL its plans + elevations + sections stacked in modelspace): run `scripts/detect_sheet_frames.py` on the sanitized DXF. It finds `XX平面图` title texts (filtering catalog rows and title-block copies; titles INSIDE cached-xref blocks are scanned too), prefers title-block frame INSERTs (`A0_V1`/`A0+0.5_V1`/`*图框*`… world bboxes) as clip windows — pitch-sized windows halve elongated sheets (13号 加长A0 held two towers in one frame) — refines each clip to the wall bbox inside it, and computes per-floor `offset`s by voting-based grid-line correlation (label-free; TArch grids live on layer `DOTE`, not `AXIS`). When a frame has NO axis geometry at all, it falls back to wall-profile correlation (length-weighted wall-position histograms, x and y independently, coverage+peak-ratio gated) before surrendering to the clip-corner anchor — clip corners track wall bboxes and drift by whole bays when balconies differ. Auxiliary-titled frames (非机动坡道/无障碍改造/人防…) are flagged and never become the alignment reference (a bike-ramp frame once anchored a whole tower to nothing). Never model such a file as one floor (all sheets superimpose) and never stack frames without offsets (floors staircase away diagonally — the classic broken output). Multi-floor titles (四、六、八层平面图 / 十一至十四层平面图) are expanded into one config entry per storey sharing the frame's clip/offset — hand-copying N entries is where floors silently vanished (13号 b2). Read its report: `WEAK grid match` floors need overlay verification; `wall-correlated` floors deserve one overlay check too; elevation/section frames are listed for floor heights with a PER-FRAME `ladder:` of DIM_ELEV values plus a `suggested storey table` line (uniform-step chain) — the suggestion is evidence, not a decision: fill `z`/`height` yourself after checking the 剖面 ladder (stair sections beat at half-storey rhythm; podium/machine floors differ). Frame clips can swallow the sheet above/below (refine bbox includes between-sheet strips): if a floor's footprint depth is ~2-4x its siblings, cluster its wall y-midpoints and cut the clip band to the plan's own row.
|
||||
- Align floors by structural grid or repeated control axes. Use millimeters-to-meters scale (`0.001`) unless the report proves the CAD is already in meters.
|
||||
- Floor keys: `floor_sort_key` treats a leading `B` as basement (sorted below ground). Do not invent keys like `B1F` for "Building 1 Floor" — use per-building specs instead, and set explicit `floor_order` whenever keys are nonstandard.
|
||||
- When CAD linework has enough exterior/interior boundary signal, enable generated footprints for floor slabs and roof caps. Prefer footprint polygons over rectangular floor bounds for visual/digital-twin presentation. Footprints are hulled PER proximity cluster (`footprint_cluster_linkage`, 6 m): a floor holding two disconnected masses (13号 twin towers in one floor key) gets separate hulls — a single concave hull would bridge the void and `use_footprint_slabs` would lay plates across it; genuinely linked wings stay merged because the 连廊 walls connect the clusters.
|
||||
@@ -134,8 +134,8 @@ A folder like `建筑-1#厂房 / 2#厂房 / 3#辅房 / 总图` is a CAMPUS: seve
|
||||
- Place buildings with a site manifest: from 总图/定位图 (prefer a "带轴号(可点坐标)" version if present) measure each building's anchor point and rotation, then assemble per-building GLBs in the viewer/scene with those transforms. Record the manifest (building -> position/rotation/source) in the notes file.
|
||||
- Proven placement recipe (贝昂 case): find the building's envelope rectangle in the site drawing (layer 面积核算/建筑轮廓线) — its edge lengths must equal the model's wall-envelope bbox 1:1 (here 90.2 x 42.2 m exactly), edge angle gives rotation (7.57°), the corner matching the model's (min x, min y) gives translation. Resolve the 180° flip by densest-feature voting (e.g. machine-room walls inside a known sub-rect). Then EITHER merge at spec level (transform all segments/footprints/caps into site-local meters and append a SITE context floor) and export one GLB, OR keep per-building GLBs plus transforms in the manifest. Pick a site-local origin (用地红线 min corner), never raw surveying coordinates — float32 breaks at 349 km.
|
||||
- Anchor placement on WALL evidence, never roof/eave envelopes: 屋面 outlines include canopies and asymmetric overhangs — concentric placement against one put 2# 0.45 m off (26 cm INSIDE its neighbour). Best anchors, in order: corner coordinate callouts (X=/Y= texts), wall lines, envelope rects whose edges equal the wall bbox exactly.
|
||||
- Site plans without per-building envelope rects (27号 pattern): building outlines may hide on odd layers (EVTR!) — match each closed polyline to its nearest 楼栋 label, then register the model footprint onto the outline by point-to-edge ICP (brute-force angle + translation refine, trim worst 10%). Constrain the angle window when the outline is visibly axis-aligned — balcony bumps love a tilted false minimum. A building with NO drawn outline can still be anchored from its DIM_COOR corner callouts alone (pair X=/Y= texts, drop points that fall on the garage outline / fire-pad rects), and registering the UNION of several floors' footprints beats one floor when upper wings overhang. Surveying convention on both 13号/27号 site plans: drawing x = 测绘Y (east), drawing y = 测绘X (north), meters.
|
||||
- Buildings named on the site plan but with NO delivered drawings (27号 3#/4#): build honest massing specs from the site outline x storey count x storey height (labels like `22F` sit next to each outline; heights from the sibling tower's ladder). Mark them as 总图轮廓体量 in the spec description and campus notes — never silently fake a detailed model.
|
||||
- Site plans without per-building envelope rects (27号 pattern): building outlines may hide on odd layers (EVTR!) — match each closed polyline to its nearest 楼栋 label, then register the model footprint onto the outline with `scripts/register_site_outlines.py` (point-to-edge ICP: brute-force angle + translation refine, trim worst 10%; emits a manifest-ready placement + residual). Constrain `--angle-window` when the outline is visibly axis-aligned — balcony bumps love a tilted false minimum (2# found a 10.75° pit). A building with NO drawn outline can still be anchored from its DIM_COOR corner callouts alone (pair X=/Y= texts, drop points that fall on the garage outline / fire-pad rects), and registering the UNION of several floors' footprints (`--floors F1 F2 F4`) beats one floor when upper wings overhang. Judge residuals: 0.06 m = outline equals model; 0.5-1 m normal with balconies; >2 m = wrong outline/floors, check the overlay. Surveying convention on both 13号/27号 site plans: drawing x = 测绘Y (east), drawing y = 测绘X (north), meters.
|
||||
- Buildings named on the site plan but with NO delivered drawings (27号 3#/4#): `scripts/massing_from_outline.py --outline pts.json --storeys 22 --height 3.0` builds an honest massing spec (outline-edge walls, footprint slabs, top cap, description marked 总图轮廓体量) and prints manifest-ready anchors — never silently fake a detailed model. Storey counts come from the `22F` labels next to each outline; heights from the sibling tower's ladder.
|
||||
- Adjacent-building gap sanity check is mandatory: compute the wall-to-wall gap in the shared-edge frame. ~0.15-0.30 m means 贴建 with an expansion joint (变形缝) — corroborate with the neighbour's roof labeled on this building's roof plan and matching floor elevations. Several metres means fire separation. A NEGATIVE gap (overlap) is always a placement bug. Cross-check the chosen position against the boundary: if a hypothesis (e.g. a 10 m fire gap) pushes the building through 用地红线, the hypothesis is wrong.
|
||||
- Site context is a deliverable, not decoration — a campus scene with only a few boundary lines reads as broken. Run `scripts/site_context_from_dump.py` on the 总图/定位图 dumps: it emits ready-to-merge floors for ground (用地红线 footprint slab), roads + parking stalls (lines, arcs, block-expanded 车位 INSERTs), fence (围墙 as 1.8 m railings), street trees (行道树 INSERT points as green posts, custom `trees` category), and low-confidence massings for context structures drawn only in the site plan (连廊/门卫/消控室, named by nearest label). It takes one plan-copy window (site sheets usually hold several scheme copies), a per-source unit scale (总图 in meters, 定位图 copies in mm), and an exclude-quad so the real building model replaces its own site outline. Buildings that have their own drawing sets get real models placed by the manifest — never fake them as massings.
|
||||
|
||||
|
||||