# Multi-Frame Sheets and TArch/天正 ## Contents 1. Detecting sheet walls 2. Alignment evidence 3. Titles and storeys 4. Clip risks 5. TArch mapping preset ## Detecting Sheet Walls Chinese architectural DWGs often place all plans, elevations, sections, and details in one modelspace. Run `detect_sheet_frames.py`; never model the whole file as one floor. The detector: - scans plan titles in modelspace and cached blocks; - rejects catalog/title-block copies and auxiliary titles; - prefers title-block INSERT bboxes over pitch-only windows; - expands enumerated/ranged titles such as `三、五层` and `十一至十四层`; - emits a config skeleton plus a Markdown evidence report. Pass every detector output config to audit with `--frames`. Account for every detected plan frame in extraction config or `discarded_frames` with a nonempty reason. The detector emits sheet-level proposals. Two different plan titles can sit inside one title-block/frame INSERT and therefore receive the same broad clip (for example `一层平面图` plus `夹层平面图`, or `二层平面图` plus `十六层平面图`). Never duplicate that shared clip across floors. Split it at the wall-cluster gap between title positions, then recompute each floor offset. Use independent declared area/storey evidence to prove the split; a roughly 2× footprint is the characteristic failure signal. ## Alignment Evidence Prefer structural-grid voting. TArch grids often live on `DOTE`, not `AXIS`. When through grids are absent, accept tick-grid voting. When no axes exist, use wall-profile correlation independently in X/Y. Use clip-corner anchoring only as a weak fallback. Require overlay review for `WEAK grid match` and `wall-correlated` results. The audit cross-floor datum gate must reject a strong correlation peak at a nonzero shift; envelope centers alone cannot detect a floor placed into the wrong tower slot. Never stack frames without offsets. That preserves sheet-layout pitch and creates the classic diagonal staircase building. ## Titles and Storeys Read per-frame elevation ladders from section/elevation frames, but treat suggested storey tables as evidence rather than truth. Stair sections can contain half-storey rhythms; podium, machine-room, and roof heights differ. Set explicit `z`, `height`, and `floor_order`. The schema rejects floor-order gaps and ghost keys. ## Clip Risks Title-block or refined clips can still swallow adjacent rows, details, legends, or revision tables. Investigate when a footprint dimension is 2-4x its siblings, exceeds declared area, or contains distant sliver polygons. Tighten both X/Y clip bands or use evidence-backed isolated-cluster filtering; do not simply raise noise thresholds until the artifact disappears. Inspect the final browser screenshot too: repeated floating strips at every storey usually mean off-envelope plan symbols survived the clip. ## TArch Mapping Preset Start consciously from this calibration, then inspect actual top layers: - walls: `WALL`, `*WALL*`, `*墙*` - columns: `COLUMN`, `*COL*` - glazing: `CURTWALL`, `*GLAZ*`, `*幕墙*`, `*玻璃*` - roof: `屋面`, `*屋顶*` - detail: `STAIR`, `EVTR`, `平面`, `开口` - grid: `DOTE`, `AXIS` Doors/windows may both be INSERTs on `WINDOW`, with leaf geometry on layer `0`. Use block-name classification: ```json { "expand_blocks": ["$TCHSYS$*", "$DorLib2D$*"], "block_name_categories": { "glazing": ["$TCHSYS$WIN2D*"], "doors": ["$DorLib2D$*"] } } ``` Exclude annotation/frame layers such as `*-IDEN`, `*图签*`, `PUB_*`, `DIM_*`, `*TEXT*`, `面积核算`, `格子线`, `SEC-*`, `立面`, `剖面`, `家具`. TArch column fills can be HATCH-only; pull structure from the structural drawing set instead of inventing columns.