67 lines
3.0 KiB
Markdown
67 lines
3.0 KiB
Markdown
# Multi-Frame Sheets and TArch/天正
|
|
|
|
## Contents
|
|
|
|
1. Detecting sheet walls
|
|
2. Alignment evidence
|
|
3. Titles and storeys
|
|
4. Clip risks
|
|
5. TArch mapping preset
|
|
|
|
## Detecting Sheet Walls
|
|
|
|
Chinese architectural DWGs often place all plans, elevations, sections, and details in one modelspace. Run `detect_sheet_frames.py`; never model the whole file as one floor.
|
|
|
|
The detector:
|
|
|
|
- scans plan titles in modelspace and cached blocks;
|
|
- rejects catalog/title-block copies and auxiliary titles;
|
|
- prefers title-block INSERT bboxes over pitch-only windows;
|
|
- expands enumerated/ranged titles such as `三、五层` and `十一至十四层`;
|
|
- emits a config skeleton plus a Markdown evidence report.
|
|
|
|
Pass every detector output config to audit with `--frames`. Account for every detected plan frame in extraction config or `discarded_frames` with a nonempty reason.
|
|
|
|
## Alignment Evidence
|
|
|
|
Prefer structural-grid voting. TArch grids often live on `DOTE`, not `AXIS`. When through grids are absent, accept tick-grid voting. When no axes exist, use wall-profile correlation independently in X/Y. Use clip-corner anchoring only as a weak fallback.
|
|
|
|
Require overlay review for `WEAK grid match` and `wall-correlated` results. The audit cross-floor datum gate must reject a strong correlation peak at a nonzero shift; envelope centers alone cannot detect a floor placed into the wrong tower slot.
|
|
|
|
Never stack frames without offsets. That preserves sheet-layout pitch and creates the classic diagonal staircase building.
|
|
|
|
## Titles and Storeys
|
|
|
|
Read per-frame elevation ladders from section/elevation frames, but treat suggested storey tables as evidence rather than truth. Stair sections can contain half-storey rhythms; podium, machine-room, and roof heights differ.
|
|
|
|
Set explicit `z`, `height`, and `floor_order`. The schema rejects floor-order gaps and ghost keys.
|
|
|
|
## Clip Risks
|
|
|
|
Title-block or refined clips can still swallow adjacent rows, details, legends, or revision tables. Investigate when a footprint dimension is 2-4x its siblings or contains distant sliver polygons. Tighten the clip band or use isolated-cluster filtering; do not simply raise noise thresholds until the artifact disappears.
|
|
|
|
## TArch Mapping Preset
|
|
|
|
Start consciously from this calibration, then inspect actual top layers:
|
|
|
|
- walls: `WALL`, `*WALL*`, `*墙*`
|
|
- columns: `COLUMN`, `*COL*`
|
|
- glazing: `CURTWALL`, `*GLAZ*`, `*幕墙*`, `*玻璃*`
|
|
- roof: `屋面`, `*屋顶*`
|
|
- detail: `STAIR`, `EVTR`, `平面`, `开口`
|
|
- grid: `DOTE`, `AXIS`
|
|
|
|
Doors/windows may both be INSERTs on `WINDOW`, with leaf geometry on layer `0`. Use block-name classification:
|
|
|
|
```json
|
|
{
|
|
"expand_blocks": ["$TCHSYS$*", "$DorLib2D$*"],
|
|
"block_name_categories": {
|
|
"glazing": ["$TCHSYS$WIN2D*"],
|
|
"doors": ["$DorLib2D$*"]
|
|
}
|
|
}
|
|
```
|
|
|
|
Exclude annotation/frame layers such as `*-IDEN`, `*图签*`, `PUB_*`, `DIM_*`, `*TEXT*`, `面积核算`, `格子线`, `SEC-*`, `立面`, `剖面`, `家具`. TArch column fills can be HATCH-only; pull structure from the structural drawing set instead of inventing columns.
|